The short answer
Safe solar wiring rests on three rules: a fuse on the positive cable of each circuit, a cable size suited to the current and the length, and a charge controller between the panels and the battery. High currents are dangerous: have the installation fitted or checked by a professional.
The order of connection
The order of connections matters. The usual order is: battery first (with its fuse), then the controller, then the panels last; you disconnect in the reverse order. Read your controller's manual, which takes precedence.
A panel exposed to light produces current even if it is badly connected: cover it or disconnect it before working.
Panels in series or in parallel
In series, the voltages add up and the current stays that of one panel. In parallel, the currents add up and the voltage stays that of one panel. Victron gives the example of three 12 V panels of about 22 V Voc wired in series to a 75 V MPPT controller.
Series reduces the current and therefore the cable size needed, but requires an MPPT controller that accepts the total voltage; shade on a single panel then penalises the whole string. Parallel keeps a low voltage but calls for thicker cables; it suits identical panels.
| Criterion | Series | Parallel |
|---|---|---|
| Voltage | adds up | that of one panel |
| Current | that of one panel | adds up |
| Cable on the panel side | can be thinner | thicker |
| Controller | check the maximum input voltage | check the maximum current |
| Shade on one panel | penalises the whole string | penalises the others less |
Cable sizes: Victron's table
Victron provides a table of recommended cable sizes for a voltage drop of 0.259 V, with the total round-trip length included (positive plus negative), contacts not included. It aims for a voltage drop below 2.5%.
The table gives the maximum recommended current by cable size and length. The longer the cable, the less current it carries for the same size:
| Size | up to 5 m | up to 10 m | up to 15 m | up to 20 m |
|---|---|---|---|---|
| 6 mm² | 18 A | 9 A | 6 A | 5 A |
| 16 mm² | 48 A | 24 A | 16 A | 12 A |
| 35 mm² | 105 A | 53 A | 35 A | 26 A |
| 70 mm² | 210 A | 105 A | 70 A | 53 A |
A simple rule for estimating
For a length of up to 5 m, Victron suggests dividing the current by 3 to get the size in mm². Example from the source: 200 A gives about 66 mm². Two cables in parallel must add up to the recommended size: two 35 mm² cables are equivalent to one 70 mm² cable.
These values are guidelines, not a validation of your installation: temperature, cable type and the voltage drop you accept change the result. A professional will size it for your case.
Fuses
The fuse goes on the positive cable. Each appliance connected to the battery has its own fuse, whatever its size. Between the panel array and the controller, a fuse is required according to local rules.
Rating: for a single appliance, take the lower of the appliance's rating and the cable's; for several appliances, the cable's rating. With a lithium battery, at least one fuse must have a breaking capacity greater than or equal to the battery's maximum short-circuit current: Victron calls this a mandatory safety requirement.
- Fuse on the positive, not on the negative.
- One fuse per appliance connected to the battery.
- Sufficient breaking capacity, especially with lithium.
- The measuring shunt goes on the negative, before the battery.
A worked example and mistakes to avoid
Suppose a circuit between a controller and the battery must carry 30 A, with 3 m of cable in total, round trip included. Victron's table gives 48 A for 16 mm² up to 5 m: this size is suitable, with a margin. With 12 m of total length, the up-to-15 m column gives only 16 A for 16 mm², and you would need to move up to 35 mm² (35 A).
The divide-by-3 rule gives an order of magnitude for short lengths: 30 / 3 = 10 mm². The two methods do not give the same result, because the rule is an approximation. When they differ, choose the larger size.
Wiring mistakes are rarely spectacular at first: they heat up, then cause problems over time. Here are the ones to avoid:
- A cable that is too thin or too long: it heats up and the voltage drop reduces charging.
- A fuse on the negative, or without sufficient breaking capacity.
- Loose connections or poorly crimped lugs.
- Cables rubbing against sharp edges, without grommets or sleeving.
- A single large fuse for several appliances instead of one fuse per appliance.
When to call a professional
Beyond a few amps, a wiring error can cause overheating or a fire. Call an electrician or an installer for battery circuits, the DC-DC charger and anything at 230 V. Our guide on regulations and electrical safety complements this point. This guide describes principles, does not recommend any product and does not guarantee compliance.