Safety

Vans and motorhomes: electrical safety and rules to know

VASP, fuses, cables, panels in series or parallel, MPPT, 230 V: the basics before installing solar. General information, not expert advice.

Updated on 21 November 2026.

Please note: these are French rules

The regulatory points in this guide (the VASP approval, the DREAL, the standards cited, insurers) describe the rules in force in France. The rules of another country may differ, sometimes considerably. If you live or travel elsewhere, find out locally from the competent authorities and from your insurer. We have not written any rules for other countries.

Read this first

This guide is general information, not professional advice. It does not say that an installation is “safe” or “compliant”: only a competent person who inspects your vehicle can say that. For 230 V and for high currents, call on a professional. Rules change: check them with your DREAL (the regional administration in France) and with your insurer.

VASP: what is it?

VASP stands for “véhicule automoteur spécialisé” (specialised motor vehicle). A van converted into a motorhome goes through this approval with the DREAL (individual vehicle approval) before the registration certificate is amended. The file includes, among other things, a dimensioned plan and a load distribution calculation.

According to the Groupama page read for this guide, the file relies on cited standards: NF EN 1646-1, NF EN 1648-2 (12 V electrical installations) and NF EN 721 (ventilation). If you carried out some of the work yourself, an inspection by a body such as Qualigaz or Veritas may be required. These points come from an insurer’s website: check them with your DREAL, as we were not able to read the official text itself.

If you add solar to a vehicle that is already approved, ask your DREAL whether a procedure is needed: we do not know on your behalf.

Fuses: always on the positive wire

According to Victron’s Wiring Unlimited guide, every device connected to the battery needs its own fuse, placed on the positive cable. A main fuse protects the battery, and smaller fuses protect each branch. For a single device, the rating follows the lower of the device’s current and the cable’s current; for several devices, it follows the cable’s.

A fuse is also provided between the panels and the charge controller, even though local rules vary. For a lithium battery, at least one fuse must have a breaking capacity higher than the battery’s possible short-circuit current: Victron describes this as a mandatory safety requirement.

Cables: cross-section and voltage drop

Victron recommends aiming for a voltage drop of less than 2.5%. Its table, based on the total cable length (out and back), shows for example that a 35 mm² cable carries about 105 A up to 5 m and 53 A up to 10 m. Rough rule for under 5 m: divide the current by 3 to get the cross-section in mm². These are the manufacturer’s orders of magnitude; calculate your specific case with Victron’s free tool or with a professional.

Use flexible, multi-strand copper cables. Avoid solid-core cables and cables intended for 230 V. For the panels, choose UV-resistant solar cables.

Total length (out + back)Max current, 10 mm² cableMax current, 35 mm² cableMax current, 70 mm² cable
up to 5 m30 A105 A210 A
up to 10 m15 A53 A105 A
up to 15 m10 A35 A70 A
up to 20 m8 A26 A53 A

Panels in series or in parallel

In series, the voltages add up. In parallel, the currents do. The total power is the sum of the panels in both cases. The total open-circuit voltage (Voc) must never exceed the charge controller’s input limit.

Victron’s example: 12 V panels with a Voc of about 22 V on a 75 V charge controller allow three panels in series. The voltage rises when it is cold: keep a margin, according to the panel’s temperature coefficient. The manual of the 100/30 and 100/50 controller gives a maximum of 100 V open-circuit.

MPPT charge controller

The charge controller acts as an intermediary between the panels and the battery. Never connect a panel directly to the battery. The Victron manual also states that the solar input is not isolated from the battery: the connections are dangerous and must not remain accessible. An MPPT controller accepts voltages higher than the battery’s, and so allows panels in series and thinner cables on the panel side. Some sites claim a gain of 20 to 30% without citing a source: we do not repeat it.

Tighten the terminals to the torque given by the manufacturer (1.6 Nm on the model cited) and check the polarity before connecting.

230 V: leave it to a professional

The 230 V inverter produces a voltage that can be lethal, and the currents on the battery side can be very high (a 2,000 W inverter draws more than 150 A at 12 V). Have this part installed and checked by a qualified electrician, including suitable residual-current protection.

Before connecting anything

This list is not exhaustive and does not replace an inspection. Also check with your insurer whether an electrical modification has to be declared.

Sources

Safety. This guide is for information only and replaces neither the manufacturer's instructions nor a professional's advice. For 230 V, high currents and any fixed installation, call a qualified professional.