Guide

Battery charging time with a 100, 200 or 400 W solar panel

How long to recharge a battery with a 100, 200 or 400 W panel: the formula, a table by season and the losses to allow for.

Updated on 22 November 2026.

The short answer

To recharge half of a 12 V, 100 Ah lithium battery (about 640 Wh), a 200 W panel takes roughly 1 day in summer around Paris, a day and a half in March, and about 5 days in December. With 100 W, count double; with 400 W, half, provided the controller and the battery accept that current.

These times come from a simple formula, detailed below. They assume a flat panel with no shade, and losses of 30%: they are orders of magnitude, not promises.

The formula

The energy produced in a day equals the panel's power, multiplied by the overall efficiency, multiplied by the number of hours of full sun. One hour of full sun corresponds to 1 kWh of light received per square metre; PVGIS, the European Commission's tool, gives the monthly averages for each place.

Overall efficiency covers heat, dust, shade, cables and the controller. Our sizing guide uses about 60 to 75%; we take 70% here.

Example: a 200 W panel, 70% efficiency, 5.73 hours of full sun (Paris in June according to PVGIS) give 200 × 0.7 × 5.73, or about 802 Wh per day. To find the charging time, divide the energy to be recharged by this figure.

The energy to recharge

A 100 Ah lithium battery at 12.8 V stores 1,280 Wh (12.8 × 100). You do not drain it to zero: Victron counts a usable capacity of 70 to 80% for lithium. If you use half the battery during the day, about 640 Wh remain to be put back.

For a van that uses 870 Wh per day (an example from our sizing guide), the question changes: you must produce at least 870 Wh each day to stay in balance, as the table below shows.

Table: days to recharge 640 Wh in Paris

The table applies the formula with PVGIS hours of full sun on a horizontal plane for Paris: 5.73 in June, 3.01 in March, 0.9 in December. A rainy day produces only a fraction of these average values.

PanelWh per day in JuneWh per day in MarchWh per day in DecemberDays for 640 Wh (June / March / December)
100 Wabout 401about 211about 631.6 / 3 / 10
200 Wabout 802about 421about 1260.8 / 1.5 / 5
400 Wabout 1,604about 843about 2520.4 / 0.8 / 2.5

The limits of this calculation

First, the monthly average smooths out grey days. Second, the table does not take the current limit into account. A 400 W panel at 70% gives about 280 W, or around 21 A at 13.5 V. Yet two datasheets for 100 Ah lithium batteries (LiTime and Redodo) state a recommended charging current of 20 A. Exceeding what the battery accepts calls for a controller set accordingly or a larger battery.

Third, the battery does not give back everything it receives. Victron states an efficiency of about 92% for its Smart lithium batteries on its product sheet: allow a margin of a few percent.

Finally, a controller accepts a maximum panel power: for example, according to the datasheets, 220 W for a Victron SmartSolar 75/15 at 12 V and 440 W for a 100/30. Beyond that, the surplus is lost.

A complete example

You have a 200 W panel, a 100 Ah lithium battery and you are in Paris in March. The battery has dropped to 50%, and about 640 Wh are missing. The panel produces about 421 Wh per day on average according to the calculation above, and the fridge, router and LEDs also take their share during the day. If you use 300 Wh per day, about 120 Wh per day remain to bring the battery back up: more than five days.

This example shows why charging time is never read in isolation. What counts is the gap between what the panels produce and what you consume at the same time. With 100 W, the balance would be negative in March: the battery would keep falling. This is also why we advise calculating your daily needs first, before comparing panels.

Recharging while driving too

The sun is not the only source. A DC-DC charger links the alternator to the leisure battery. As an order of magnitude, a Victron Orion XS 12/12-50A is rated at up to 50 A at 12 V, or about 600 W at most: up to 600 Wh for an hour on the road, if the alternator and the battery keep up. This maximum is not an average: it depends on the engine, the cables and the battery's state of charge.

In winter, when the panel does not cover consumption, this charging often becomes the main source: see our guide on solar in winter. A DC-DC charger is wired with sized cables and fuses: have it checked by a professional.

How to save charging time

A few simple steps save more than an extra panel. Clean the panels. Avoid shade, even partial. Point them at the sun when they are mobile. Reduce consumption, which lowers the energy to be put back.

Sources

Safety. This guide is for information only and replaces neither the manufacturer's instructions nor a professional's advice. For 230 V, high currents and any fixed installation, call a qualified professional.

Also worth reading

Calculate my needs

Transparency. Solanomad is funded by affiliate marketing, but this version of the site contains no partner or merchant links for now: no commission is linked to your clicks here. Learn more.