The short answer
An appliance's consumption is calculated like this: power in watts x hours of use per day = energy in watt-hours (Wh) per day. Add up all your appliances: the total is the energy your battery and panels must provide each day.
The values below are indicative. The rating plate or datasheet of your appliance remains the reference.
The formula and two unit traps
Watts measure power at a given moment; watt-hours measure energy over a period. A 20 W appliance switched on for 4 hours uses 80 Wh. Battery and fridge datasheets sometimes use amp-hours (Ah): at 12 V, 1 Ah corresponds to about 12 Wh (12 V x 1 Ah).
Another trap: a compressor fridge quotes its power when the motor is running, but the motor stops and restarts. You therefore need to think in terms of average consumption over 24 hours, not maximum power.
Indicative table of common appliances
These values are those of the site's calculator. They are orders of magnitude, not measurements made by Solanomad. For the fridge, they are consistent with the datasheets of the manufacturer Dometic, which publishes the consumption of its cool boxes in Ah per hour.
| Appliance | Power (approx.) | Use per day | Energy per day (approx.) |
|---|---|---|---|
| 12 V compressor fridge | 45 W when the compressor runs, 12 to 20 W on average | 24 h | 250 to 450 Wh |
| LED lighting | 20 W | 4 h | 80 Wh |
| Laptop | 45 W | 4 h | 180 Wh |
| 12 V fan | 15 W | 6 h | 90 Wh |
| 12 V water pump | 50 W | about 12 min | 10 Wh |
| Phone (one recharge) | 10 W | 1.5 h | 15 Wh |
| Tablet (one recharge) | 12 W | 1.5 h | 20 Wh |
| Stationary diesel (air) heater | 20 W in steady state | 8 h | 150 Wh (100 to 400 Wh) |
Start-up and standby: the hidden consumption
Some appliances draw far more at start-up than in normal running: fridge compressor, pump, diesel heater at ignition. This peak matters when choosing an inverter or a fuse, not for the total in Wh. A 12 V to 230 V inverter itself has a no-load consumption, called standby: it appears in the model's datasheet, and can be several watts. Illustrative example: 10 W of standby left on 24 hours a day costs 240 Wh, as much as a fridge. Switch the inverter off when you do not need it.
On the peak power side, Victron's datasheets give, for example, for a Phoenix 12/300 model: 300 W continuous and 1,300 W for a brief overload. An inverter should therefore not be chosen only on the power shown in large print.
A worked example: a weekend in a van
Take a fridge (300 Wh), LED lighting (80 Wh), a laptop (180 Wh), a phone recharge (15 Wh) and the water pump (10 Wh). The total is 585 Wh per day. With a 100 Ah lithium battery at 12.8 V, or about 1,280 Wh, and a usable discharge of 80%, or about 1,020 Wh, you last about 1.7 days without sun.
| Appliance | Energy per day (Wh) |
|---|---|
| Compressor fridge | 300 |
| LED lighting | 80 |
| Laptop | 180 |
| Phone | 15 |
| Water pump | 10 |
| Total | 585 |
How to measure it yourself
The best value is that of your own appliance. There are three methods: read the rating plate (power in watts or current in amps), consult the manufacturer's datasheet, or plug in a power meter for 230 V appliances. For a 12 V appliance, a battery monitor that shows the current gives the real consumption in amps; multiply by the voltage to get watts.
If the plate shows a current in amps, multiply it by the voltage: 2 A at 12 V is about 24 W. If it gives volt-amperes (VA) for a 230 V appliance, count at least as many watts, and check the datasheet: the real power may be lower.
Measure over several days, in the weather of the moment: a fridge uses more when it is hot outside, and a heater uses more in cold weather. Then keep a margin of 20 to 30% in your calculations, for the appliances you will add without thinking.
What to do next
Once you have the total in Wh per day, size the battery (aiming for several days of autonomy if you wish) and the panels, taking into account the sunshine of the month. The site's calculator does these calculations with the formulas shown. For large 230 V appliances, cooking or electric heating, the power quickly becomes incompatible with a small installation: get advice from a professional.
Common mistakes
Four mistakes come up often in autonomy calculations. They distort the total by several hundred watt-hours.
Redo this assessment whenever your equipment changes: a new fridge, a larger screen or a different heater changes the total. Note the date and the values used, to compare with what your battery monitor shows after a few days of use. If the gap exceeds 20%, look for the appliance that uses more than expected, often one on standby.
- Counting the fridge at full power 24 hours a day, instead of its average consumption.
- Forgetting small appliances left plugged in: chargers, router, inverter on standby.
- Confusing amp-hours and watt-hours, or 12 V and 230 V, in the same table.
- Not allowing for winter consumption, when heating, lighting and time spent indoors increase.
Sources
- Dometic, CFX3 support: consumption in Ah/h
- Victron Energy, Phoenix 12/300, 12/500, 24/500 and 24/800 manual: continuous and peak power
Safety. This guide is for information only and replaces neither the manufacturer's instructions nor a professional's advice. For 230 V, high currents and any fixed installation, call a qualified professional.